Project Snapshot Series Part 2: Historic Theatre Retrofit Using FRP

Project Snapshot Series Part 2: Historic Theatre Retrofit Using FRP

Structural renovation work continues on an historic, 1920s-era theater in Hollywood, California. This major renovation will improve the structural performance of the building and help ensure that theatergoers and building occupants are safe in the event of a major earthquake. We are excited to share a second update on this project that focuses on the use of fiber-reinforced polymer (FRP) for strengthening the theater’s roof diaphragm.  

Photo 1 shows the existing beautifully decorated ceiling of the theater. This ceiling is supported above by reinforced concrete trusses (see photo 2) and beams that tie into a structural slab system. The roof slab must support its own weight plus various mechanical, electrical and plumbing components. Additionally, this slab acts as a diaphragm during a seismic event and was found to be structurally deficient. FRP was chosen as the best means of strengthening the diaphragm in this case, because the material is lightweight, especially easy to install in a downward direction, and very thin. Photo 3 shows another location where FRP strips have been added for diaphragm strengthening.

Photo 1: Note the decorated ceiling, which is supported by the roof structure above.
Photo 1: Note the decorated ceiling, which is supported by the roof structure above.
Photo 2: Trusses and beams (not seen) support the theater’s roof structure. Note that FRP strips are used to provide a lightweight diaphragm-strengthening solution.
Photo 2: Trusses and beams (not seen) support the theater’s roof structure. Note that FRP strips are used to provide a lightweight diaphragm-strengthening solution.

Less noticeable, but indicated by arrows in photo 3, is that FRP anchors were used to improve the structural performance of the FRP strips. Using FRP anchors not only delays debonding of the FRP strips at the concrete interface, but also allows the FRP fabric to achieve a higher design strain and hence add more strength. The anchors are 1/2″ in diameter and embedded roughly 3″ deep in the slab. Anchors are located not only at the end of the FRP strips but also along the length of the strips. In some cases, where structural deficiency existed, bidirectional glass fabric (see photo 4) was used to strengthen the diaphragm-to-wall connection. Bidirectional fabric in this case means that the fibers run +/- 45°. This orientation of fibers makes the fabric especially suitable for resisting shear forces at the interface of the diaphragm and wall.  

Photo 3: Note FRP anchors added along FRP strips to improve FRP strip performance.
Photo 3: Note FRP anchors added along FRP strips to improve FRP strip performance.
Photo 4: Bidirectional glass FRP was used to strengthen the diaphragm-to-wall connection.
Photo 4: Bidirectional glass FRP was used to strengthen the diaphragm-to-wall connection.

Retrofit work continues on this historic 100 year old theater. We look forward to sharing more FRP applications as construction progresses. Stay tuned for more updates!    

 

Print Friendly, PDF & Email
Jason Oakley

Author: Jason Oakley

Jason is a California registered professional engineer who graduated from UCSD in 1997 with a degree in structural engineering and earned his MBA from Cal. State Fullerton in 2013. He is a field engineer who teaches specifiers about concrete anchorage and fiber reinforced polymers (FRP) in the S. California and Pacific region. Before joining Simpson Strong-Tie in 2002, he was a design engineer for 5 years working on subterranean parking lots, movie sets, offshore drilling platforms, nuclear power plants, oil refineries, blast-resistant structures, fall protection, dry-dock ship supports and vibration.